Section 2.1 : Electrical systems : Basics review

Relations between conventions

The two conventions presented above affect the connection laws between quadripoles.

Symetrical convention

Symetrical convention

Under this convention, the sum of all currents in the node between the quadripoles is null and the voltage drops are equal . The transfer matrix between the two quadripoles is therefore written

Asymmetrical convention

Asymmetrical convention

Under this convention, the difference between the currents in the node between the two quadripoles is null

and  the voltage drops are equal . The transfer matrix between the two quadripoles is therefore written .

PrécédentPrécédentSuivantSuivant